Intercooler and High Pressure Evaporator test machine.
Media: Water/Glycol, Oil
Peak Pressure Range: 1—70 Bar
Temperature Range: Ambient—150°C
Frequencies: 0—1Hz
Life cycle testing of intercoolers and high pressure evaporators, long term testing with full data logging.
Intercooler test machine.
Media: Air
Peak Pressure Range: 0.1—3 Bar
Temperature Range: Ambient—230°C
Frequencies: 0—1Hz
Life cycle testing of high temperature intercoolers, design included a cooling air circuit.
Automotive Component Durability Test machine.
Media: Oil
Peak Pressure Range: 0.5—50 Bar
Temperature Range: Ambient—150°C
Frequencies:0—5Hz
Life cycle testing of high temperature intercoolers, design included a cooling air circuit.
Vehicle Radiators test machine.
Media: Water/Glycol, Oil
Peak Pressure Range: 1—7 Bar
Temperature Range: Ambient—130°C
Frequencies: 0—1Hz
Durability testing of vehicle radiators, pressure pulsing with vibration, dual bay machine increasing test capacity.
Two bay test machine for Radiators and Intercoolers.
Media: Air
Peak Pressure Range: 0.5—5 Bar
Temperature Range: Ambient—300°C
Frequencies: 0—4Hz
Testing of intercoolers and radiators with a capacity of 60 Litres. Used for rapid life testing and for test to destruction.
Hose test machine.
Media: Water / Glycol
Peak Pressure Range: 0.2—3 Bar
Temperature Range: Ambient—120°C
Frequencies: 0—5Hz
Capacity to test up to 6 engine hoses simultaneously for life tests or until failure.
Sprinkler head test machine.
Media: Water
Peak Pressure Range:0.5—16 Bar
Temperature Range: Ambient
Frequencies: 0—1Hz
Designed to simulate water hammer effects on up to 15 sprinkler heads in one test period to ensure compliance to EU standards.